Blue Robotics
Lithium-ion Battery (14.8V, 18Ah)
Lithium-ion Battery (14.8V, 18Ah)
Couldn't load pickup availability
The Lithium-ion Battery (14.8V, 18Ah) is a high capacity custom battery pack made from high quality 18650 lithium-ion cells designed for use in the BlueROV2, BlueBoat, and fits perfectly inside a 3″ Watertight Enclosure!
Because we can’t control how the batteries are charged, used, or maintained, Blue Robotics cannot be held responsible for any damage, loss, or costs resulting from improper operation.
Specifications
| Parameter | Value | |
|---|---|---|
| Electrical | ||
| Nominal Voltage | 14.8V | |
| Nominal Capacity | 18.0Ah | 266.4Wh |
| Cell Configuration | 4S6P | |
| Maximum Continuous Current Draw* | 60A | 3.3C |
| Maximum Burst Current Draw (10s)* | 132A | 7.3C |
| Maximum Charge Current | 20A | 1.1C |
| Minimum Safe Voltage | 12V | 3.0V/Cell |
| Discharge Connector | XT90S | |
| Balance Plug | 5 pin JST-XH | |
| Thermistor Plug | 2 pin JST-XH | |
| Thermistor Type | NTC, β = 3435K | |
| Thermistor Resistance | R 25 = 10kΩ, ±1% (at 25°C) | |
| Thermistor Working Temperature | -40-110°C | -40-230°F |
| Physical (Typical) | ||
| Diameter | 74.2 ±0.3 mm | 2.92 ±0.01 in |
| Length | 146 ±2 mm | 5.75 ±0.08 in |
| Lead Length | 75 ±5 mm | 2.95 ±0.2 in |
| Weight | 1152 g | 2.54 lb |
| *see Discharging information in the "Guides" tab for more information | ||
3D Models
BATTERY-LI-4S-18AH-R1 (.zip)
Documents
Battery MSDS (.pdf)
UN38.3 Test Report (.pdf)
INR18650-30Q Data Sheet (.pdf)
Revision History
15 December 2023
- BR-100842 sales resumed
18 July 2023
- BATTERY-LI-4S-18AH-R3-RP SKU changed to BR-100842
23 September 2021
- BATTERY-LI-4S-18AH-R3-RP discontinued
11 July 2019
- R3 - Initial Release
-
Safety
Lithium-ion batteries can be dangerous if used incorrectly—and poor handling can also shorten their lifespan. To keep things safe and get the best performance, make sure to read and understand the Blue Robotics Lithium-ion Battery Guide before using your batteries.
- Use only lithium-compatible chargers with balance charge support and the correct cell count (4S or 6S).
- Never exceed a battery’s maximum voltage or minimum voltage. Overcharging = fire risk. Overdischarging = dead battery.
- Do not exceed rated charge or discharge current. This will damage the battery.
- Keep batteries dry. Water can cause internal corrosion or short circuits.
- Don’t puncture, crush, or open the battery pack. It’s not user-serviceable.
- Avoid excessive heat. Do not expose batteries to temperatures above 50 °C (122 °F).
- Do not leave batteries unattended while charging.
Because we can’t control how the batteries are charged, used, or maintained, Blue Robotics cannot be held responsible for any damage, loss, or costs resulting from improper operation.